GET_TYPE_FROM_VARNAME block
Short summary
Name |
GET_TYPE_FROM_VARNAME |
→POU type |
|
Category |
|
Conform to →IEC-standard |
not defined in IEC-standard |
Graphical interface |
|
Available since |
version 1.42.0 (for logi.CAD 3) and version 2.3.1791 of logi.RTS |
Functionality
The block returns the data type of a variable. Enter its instance path in upper case at input NAME. The data type is returned as UDINT value.
logi.cals recommends to call the GET_TYPE_FROM_VARNAME block just once for the variable to request. On the one hand the time behavior might be unpredictable and on the other hand it might take longer to determine the data type.
Restrictions for the usage:
The requested variable must have been declared with an elementary data type or an array of these elementary data types. The elementary data types are: REAL, LREAL, USINT, UINT, UDINT, ULINT, SINT, INT, DINT, LINT, TIME, BOOL, BYTE, WORD, DWORD, LWORD, STRING, CHAR, DATE_AND_TIME, DATE or TIME_OF_DAY
There must be an instance path for the requested variable. This means that the following variables cannot be requested:
variables in →functions
→in-out variables (VAR_IN_OUT)
The requested variable must writeable from each position of the application (i.e. within and outside of the POU in which the variable has been declared). This means that the following variables cannot be requested:
variables with the keyword CONSTANT
→input variables (VAR_INPUT)
→output variables (VAR_OUTPUT)
It is only allowed to use the call of the block on the right side of the assignment operator ":=" for →assignments.
Inputs, outputs, return value
|
Identifier |
Description |
|
Inputs: |
NAME |
STRING |
instance path of the variable (in upper case) |
Outputs: |
LEN |
UINT |
length (= memory size) of the variable (in bytes) or 0 |
STATUS |
USINT |
state of the operation (result code):
|
|
Return value: |
– |
UDINT |
data type of the requested variable
|
Input EN and output ENO are available when →calling the block. See "Execution control: EN, ENO" for information on input EN and output ENO.
See:
"Blocks for safe logic" whether this block is supported for developing safety-relevant applications.
"Highlighting safe logic in the FBD-editor" for the effects when using the block as a block for safe logic .
Internal error diagnostic for block
The block checks whether one of the above restrictions is violated. In such an error case, the output ENO of the block is set to value FALSE (or an equivalent). Moreover, the output STATUS returns the appropriate code (see the above table under STATUS), the output LEN returns the value 0 and the block itself returns 0 (as return value).
Example for usage within ST-editor
PROGRAM DocumentationExamples
VAR
iExampleGetTypeFromVarname : ExampleGetTypeFromVarname;
END_VAR
iExampleGetTypeFromVarname();
END_PROGRAM
FUNCTION_BLOCK ExampleGetTypeFromVarname
VAR
requestedVar : INT;
dataType : UDINT;
CheckSize : UINT;
CheckState : USINT;
CheckENO : BOOL;
END_VAR
IF dataType = 0 THEN
dataType := GET_TYPE_FROM_VARNAME(NAME := 'DOCUMENTATIONEXAMPLES.IEXAMPLEGETTYPEFROMVARNAME.REQUESTEDVAR', LEN => CheckSize, STATUS => CheckState, ENO => CheckENO);
END_IF;
ENO := dataType = 11;
END_FUNCTION_BLOCK