Symptom:

  • An application cannot be built/loaded under Windows.

  • One of the following messages is displayed (either in the Error Log or Problems view or in the file compile_result.txt) :

    path/file.h:number:number: fatal error: path/file.h: No such file or directory
    #include <path/file.h>
      ^~~~~~~~~~~~~~~~~~~~~~~
    compilation terminated.
                      from path\file.c:number:
    path\file:number:number: fatal error: path/file.h: No such file or directory
    #include <path/file.h>
    compiler-name: error: CreateProcess: No such file or directory
    It is not possible to create an application for platform "name". The installation path might be too long. Use the setting "substPluginsFolder" to substitute the path for the compiler.

Causes:

  • The installation path of logi.CAD 3 is too long. That means that this path has more than 255 characters.

  • The installation path and the path of the compiler that is used for building/loading the application result in a path with more than 255 characters.

Solution:

  • Shorten the installation path of logi.CAD 3.

  • Shorten the path that is used by the compiler. Use the following configuration method of logi.CAD 3 under Windows:

  1. Go to the folder where you installed logi.CAD 3.

  2. Locate the file logiCAD3.ini and open it in a text editor.

  3. At the end of the file, enter -DsubstPluginsFolder and enter the letter of a free drive.

    Example
    ...
    -DsubstPluginsFolder=P
  4. Save the file.

  5. Start logi.CAD 3 so that logi.CAD 3 uses the correspondingly shortened path to build and load the application.

Observe:

  • When logi.CAD 3 is exited properly, the drive is released again

  • During the operation of logi.CAD 3, do not manipulate the SUBST assignment of this drive under Windows. Otherwise irregularities might occur when building/loading applications.

  • Do not use Windows settings that permit longer paths than 255 characters. These settings are ignored by logi.CAD 3.

More useful information: Cannot build or load application