Wrong names/data types might be displayed when debugging

Symptoms for control flow debugging:

  • When debugging an ST function block that is used in an ST program, the Variables view of the Debug perspective displays the name of the program instead of the name of the function block instance.

  • For in-out variables (= VAR_IN_OUT), the Variables view of the Debug perspective displays an internal name instead of the actual name. Likewise, an internal data type is displayed instead of the actual data type.
    Example: LC_VD_IO1 is displayed instead of the name IO1. LC_TD_INT is displayed instead of the data type INT.

Workaround: none existing

images/s/b2ic8e/9012/1ca6q62/_/images/icons/emoticons/information.svg logi.cals recommends to install and use the most current versions of logi.CAD 3 and the runtime system so that the latest features and problem fixes according to the release notes are provided in the used version.


Did this article help you? Did you find the requested information in this user documentation?
If not, contact the support team of logi.cals. State your questions or suggestions to improve/enhance the user documentation as detailed as possible.