"Values of Variables" view does not display any values for Controllino or Arduino Nano

Symptom: The Values of Variables view does not display values for variables on a →Controllino or →Arduino Nano.

Cause: logi.CAD 3 has been started with the option LC3useRTS3MetaData=false.

Solution: Make sure that the generation of metadata is enabled before logi.CAD 3 is started.

  1. Go to the folder where you installed logi.CAD 3.

  2. Locate the file logiCAD3.ini and open it in a text editor.

  3. Search for -DLC3useRTS3MetaData.

  4. If this configuration variable is defined with value false, define the value true.

    Example for corrected lines
    ...
    -Xms256m
    -Xmx6144m
    -DLC3useRTS3MetaData=true

    images/s/b2ic8e/9012/1ca6q62/_/images/icons/emoticons/information.svg By default, the generation of metadata is activated in logi.CAD 3. However, the generation has been deactivated due to -DLC3useRTS3MetaData=false (after the option -vmargs).

  5. Save the file.

images/s/b2ic8e/9012/1ca6q62/_/images/icons/emoticons/information.svg logi.cals recommends to install and use the most current versions of logi.CAD 3 and the runtime system so that the latest features and problem fixes according to the release notes are provided in the used version.