Error message when expanding objects


Symptom:

If you exand an object (e.g. an ST-object) in the project explorer to show the sub levels of the object, the following errors are shown:

  • An exception occurred invoking extension: com.logicals.iec.st.ui.projectexplorer for object L/<projectName/src/<fileName>.<extension>

  • Problems occurred when invoking code from plug-in: "org.eclipse.ui.navigator".

Cause:

The problem is caused by the mixed upper and lower case of the file extension. Example: iecSt, iecPLC, IeCfbd

Solution:

Take care that the file extension contains only upper case or only lower case letters (e.g. iecst or IECST). Usually, it is not necessary to enter the file extension in logi.CAD 3.

images/s/b2ic8e/9012/1ca6q62/_/images/icons/emoticons/information.svg logi.cals recommends to install and use the most current versions of logi.CAD 3 and the runtime system so that the latest features and problem fixes according to the release notes are provided in the used version.